Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Select Language
First, test wiring and method
1. Test wiring diagram
Figure 4-11 shows the three test wirings, the instrument used is not less than 0.5. Prepare more than 20 alcohol thermometers, disperse 10 or more in the circumferential and axial directions of the teeth, place 2 in the crotch, and measure the initial temperature of the core and room temperature. When conditions permit, temperature and recording can be measured with an infrared camera.
2. Calculation of excitation coil and measuring coil
The number of excitation coil turns is calculated according to formula (4-5)
In the formula B - core core magnetic density, generally take 1T or 1.4T (for indirect cooling, turbo generators below 100MW and small capacity hydro-generators can take 1T; for direct cooling of turbo generators and large Hydrogenerator takes 1.4T)
U1——excitation coil voltage, V;
S——the cross-sectional area of the stator core, cm;
L——the axial length of the stator core, cm;
K——core filling factor, taking 0.93;
L1——the total length of the stator core, cm;
L2——the width of the stator core ventilation groove, cm;
n - the number of ventilation slots;
H——the stator core back height, cm;
D1——the effective outer diameter of the stator core, cm;
D2——the effective inner diameter of the stator core, cm;
H1——the height of the stator core, cm.
Excitation current is calculated according to formula (4-6)
Second, the test steps and precautions
(1) Short-circuit the stator windings to ground with a 50mm2 cross-section. If the stator winding has a grounding point, it only needs to be short-circuited and cannot be grounded.
(2) Wire the wiring diagram (see Figure 4-n) so that the excitation coil and the measuring coil are perpendicular to each other.
(3) Turn on the power, quickly turn off the power after reading the indicator value, and calculate the actual magnetic density B' according to formula (4-9).
B'=U2/4.44fSW2=45U2/SW2
U2 in the formula - measuring the voltage value induced by the coil,
W2 - measure the number of turns of the coil, 匝.
The actual magnetic density B' should be consistent with the selected value. If the difference is large, the number of turns should be adjusted appropriately.
(4) Turn on the power again, and after 10 minutes, check the heat condition with an infrared camera. If it is found to be significantly too high, smoking or redness, the test should be stopped and recorded. The meter value or the infrared temperature measurement value is read every 10 minutes, and the power is turned off after 90 minutes (when the magnetic density is IT) or 45 minutes (when the magnetic density is 1, 4T), and the test is terminated.
(5) Note:
1) The excitation and measuring coil wires should be well insulated and do not touch the iron core (metal sheath wires or armored cables cannot be used).
2) Measures should be taken to prevent metal objects from falling into the generator.
3) Measures should be taken to prevent ventilation from affecting temperature.
4) If the local hot spot is found, the temperature difference is not obvious, the magnetic density can be increased to 1.2-1.4T, or the test voltage can be appropriately increased.
(6) Measurement data calculation formula:
Where t0 - the initial temperature of the iron core teeth, ° C;
BT—Test magnetic density, according to the test requirements, take 1T or 1.4T.
Third, the analysis and judgment of test results
(1) Magnetic density at 1T, the highest temperature rise of the tooth is not more than 25K, and the maximum temperature difference of the tooth is not more than 15K.
(2) The unit loss is not more than 1.3 times the reference value, which is specified by itself at 1.4T.
April 10, 2023
September 22, 2022
March 17, 2022
April 21, 2023
April 19, 2023
May 13, 2023
May 03, 2023
Through years of technical research and development and practical experience, Yongrong Power Co., Ltd. has developed a new set of cast aluminum manufacturing process, making its products in strength,...
The rotor with shaft is a kind of widely developed and adopted motor design, also known as the magnetic pump rotor, compared with the ordinary motor, it adopts different design concept of the...
Progressive punching is an efficient self-riveting process of fixed rotor, which can realize large-scale and precise riveting operation and is suitable for mass manufacturing production line. The...
Laser cutting provides greater precision in stator and rotor machining, using a highly focused beam that acts as a heat-affected zone during cutting without causing extensive thermal damage to...
Email to this supplier
April 10, 2023
September 22, 2022
March 17, 2022
April 21, 2023
April 19, 2023
May 13, 2023
May 03, 2023
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.